product features:
Rated Voltage:GTO-10 10KV
GTO-15 15KV
Testing Voltage:GTO-10 20KV
GTO-15 30KV
Rated temp:≤150℃
Conductor: tinned copper wire
Insulator:Silicone rubber
By the UL1581 VW-1 perpendicular combustion experiment
Applicable to electric,electrical appliance,lighting etc.high temperature high voltage.
wire print:
GTO-10 INTEGRAL SLEEVE 18AWG(0.823mm²) 150℃ 10000V (UL) C(UL) JY E226224 ROHS
GTO-15 INTEGRAL SLEEVE 14AWG(2.08mm²) 150℃ 30000V (UL) C(UL) JY E226224 ROHS
GTO-15 INTEGRAL SLEEVE 18AWG(0.823mm²) 150℃ 30000V (UL) C(UL) JY E226224 ROHS
|
ITEMS
|
Technical Datas
|
Applied Standard
|
|
appearance
|
Smooth even without loose
|
UL814
UL879
UL1581
|
|
Vol. test
|
GTO-10
|
20KV/1h
|
|
GTO-15
|
30KV/1h
|
|
insulation
mechanical
character
|
Before aging
|
Tensile strength
|
≥5.5N/mm²
|
|
Break elongation rate
|
≥250%
|
|
After aging
(210±1℃×1440h)
|
Tensile strength
|
60% of the tensile strength before aging
|
|
Break elongation rate
|
25% of the elongation rate before aging
|
|
harmful substance control
|
COMPLY WITH ROHS
|
EU—2002/95/EC
|
|
conductor
|
insulation
|
Max. conductor resistance
Ω/ km
|
Reference weight
Kg/km
|
|
Spec.
AWG
|
structure
NO./mm
|
Nominal thickness
mm
|
Nominal diameter
mm
|
allowance
mm
|
|
GTO-10
(18AWG)
|
19/0.25
|
2.64
|
6.53
|
±0.20
|
23
|
49
|
|
GTO-15
(18AWG)
|
19/0.25
|
2.70
|
6.80
|
±0.20
|
23
|
54
|
|
GTO-15
(14AWG)
|
42/0.25
|
3.80
|
9.40
|
±0.20
|
9.90
|
102
|