Product Features
·Rated Voltage:600V
·Rated temperature:125℃
·Conductor: tin-coated, nickel-coated or silver-coated copper wire
·Insulator: XLPE
E206992 UL AWM3297 (18AWG、16AWG) 125℃ 600V VW-1 CUL AWM IA 125℃ 600V FT1 HUA CHENG CABLE
|
Items
|
Technical data
|
Applied standard
|
|
Outer appearance
|
Smooth, even, without loose
|
UL758
UL62
UL1581
|
|
Spark test
|
AC6KV /0.15 S
|
|
Vol. test
|
2KV/1 min
|
|
mechanical properties of insulation material
|
Before aging
|
Tensile strength
|
≥13.79N/mm²
|
|
elongation at break
|
≥300%
|
|
After aging
|
Tensile strength
|
80% of the tensile strength before aging
|
|
(158±1℃×168h)
|
elongation at break
|
80% of the elongation before aging
|
|
Poisonous substance control
|
Comply with ROHS rule
|
EU—2002/95/EC
|
|
AWM 3297 125℃ 600V
|
|
Spec.
|
Section
|
conductor
|
insulation
|
OD
|
Conductor resistance
20℃
|
|
structure
|
diameter
|
Nominal thick
|
Min. thick
|
nominal
|
allowance
|
|
AWG
|
mm²
|
No./mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
Ω/KM
|
|
18
|
0.823
|
33/0.18
|
1.20
|
1.52
|
1.37
|
4.24
|
±0.20
|
23.20
|
|
16/0.254
|
|
16
|
1.310
|
26/0.254
|
1.55
|
1.52
|
1.37
|
4.59
|
±0.20
|
14.6
|